๐Ÿ›ก๏ธ
TradeAssistIQ
How it works
โ— Beta โ€” Ireland
Try Free โ†’

On-site fault diagnosis.
Answers in seconds.

Stop diagnosing from memory or scrolling through PDFs. TradeAssistIQ gives heating engineers instant, actionable answers โ€” fault code meanings, diagnostic steps, component test values, and the most likely fix. For every major boiler, heat pump, and renewable system.

Built for heating and renewable energy engineers in Ireland and the UK

No account needed ยท No credit card ยท Free during beta

โœ“ Gas Boilersโœ“ Oil Boilersโœ“ Heat Pumpsโœ“ Electric Showersโœ“ Shower Pumpsโœ“ Ventilation Systems
VaillantBaxiWorcester BoschIdealViessmannGlow-wormAristonAlphaVokeraGrantFirebirdWarmflowDaikinMitsubishiSamsungIntergasPottertonFerroliNavienATAGVaillantBaxiWorcester BoschIdealViessmannGlow-wormAristonAlphaVokeraGrantFirebirdWarmflowDaikinMitsubishiSamsungIntergasPottertonFerroliNavienATAG

Type a fault code. Get the full picture.

Real output from a real query. Every answer includes fault meaning, most likely causes, diagnostic steps, expected test values and the most likely fix.

๐Ÿค–
AI Diagnostic
โ— Online โ€” TradeAssistIQ
Engineer
Vaillant F28 โ€” combi boiler, keeps locking out after ignition attempt
TradeAssistIQ
SOURCE: Vaillant Technical Manual ยท CONFIDENCE: High
The boiler has failed to ignite / no flame detected. Most likely a gas supply or ignition issue.
MOST LIKELY CAUSES
1. Gas supply interrupted or working pressure too low
2. Ignition electrode worn, contaminated or mispositioned
3. Flame sensor/ionisation probe fault
4. Gas valve not opening or low gas valve output
CHECK THESE FIRST
1. Gas supply & working pressure
Test: Check gas meter, isolation valves open, test inlet working pressure at appliance.
Expected: Minimum 18 mbar at working rate on natural gas.
If wrong: Restore gas supply before proceeding.
2. Ignition electrode
Test: Inspect electrode tip, gap and lead. Check for carbon tracking or cracking.
Expected: Clean tip, correct gap, no damage to lead or ceramic.
If wrong: Replace electrode assembly.
EXPECTED VALUES
โ€ข Gas working inlet pressure: min 18 mbar (nat. gas)
โ€ข Ionisation signal: typically 1โ€“10 ยตA when flame established
โ€ข Gas valve resistance: check manufacturer data
Most likely fix: Prove gas supply and inlet pressure first. If pressure is correct, inspect and test the ignition electrode and ionisation probe before replacing the gas valve.
โš ๏ธ Gas work must only be carried out by a RGI registered engineer. Isolate electrical supply before opening the appliance.

This is a real diagnostic output โ€” not a mock-up. Try it yourself free โ†’ Start diagnosing

On-site in three steps

No manuals. No hold music. No guesswork.

1
Tell it what you've got
Type the brand, model and fault code โ€” or just describe what the unit is doing. Plain English works fine.
"Ideal Logic F1" or "Daikin Altherma 7H-01" or "Vaillant combi keeps losing pressure"
2
Get the full diagnosis instantly
TradeAssistIQ searches its verified fault code database and AI knowledge base, returning the fault meaning, most likely causes, diagnostic steps, expected component test values and the most likely fix.
3
Fix it with confidence
Follow the verified diagnostic path. Prove the fault before replacing parts. Every answer includes the relevant safety notice for the appliance type.
View full how-to-use guide โ†’

Everything you need on the job

From fault codes to component test values โ€” all in one place

โšก
Instant fault code lookup
Type any fault code and get the full diagnosis โ€” fault meaning, causes and fix path immediately. No more scrolling through PDFs on a job.
๐Ÿ”ฌ
Component test values
Verified resistance, voltage, pressure and flow rate values for the components you're testing. Prove the fault before you replace anything.
๐Ÿ”ฅ
All major appliance types
Gas boilers, oil boilers, heat pumps, electric showers, shower pumps and ventilation โ€” all covered from one tool.
๐Ÿง 
AI + verified database
Every answer comes from a verified fault code database first. AI fills the gaps. No hallucinated values โ€” database-verified readings only.

Free now. Simple pricing after.

Use it completely free during beta. No card, no commitment. When beta ends, pick the plan that suits you.

RIGHT NOW
Free
During beta โ€” no card needed
โœ“ Full fault code database
โœ“ AI diagnostic assistant
โœ“ Component test values
โœ“ All appliance types
Start Free Now โ†’
ANNUAL โ€” BEST VALUE
โ‚ฌ149.99
per year
Save โ‚ฌ29.89 vs monthly
โœ“ Everything in monthly
โœ“ 2 months free
โœ“ Locked-in rate
โœ“ First access to new features
Try Free First โ†’
๐Ÿ›ก๏ธ

Ready to diagnose faster?

Join heating engineers already using TradeAssistIQ in beta. Free to use, no account needed, no card required.

Start Diagnosing Free โ†’

No account ยท No credit card ยท Free during beta